Technical data, Switching frequency−dependent output currents – Lenze 8400 motec Manual User Manual

Page 36

Advertising
background image

Technical data

Rated data
Operation at increased rated power at 400 V mains voltage

4

l

36

EDS84DG752 EN 4.0

Switching frequency−dependent output currents

Output currents [A] at switching frequency

2 kHz

4 kHz

8 kHz

16 kHz

Type

I

arated2

I

aM2

I

arated4

I

aM4

I

arated8

I

aM8

I

arated16

I

aM16

E84DGDVB3714

1.6

2.6

E84DGDVB5514

2.2

3.6

E84DGDVB7514

2.9

4.8

E84DGDVB1124

3.8

6.4

E84DGDVB1524

1)

4.7

7.8

E84DGDVB2224

6.7

11.2

E84DGDVB3024

1)

8.7

14.6

E84DGDVB4024

11.4

19.0

E84DGDVB5524

15.6

26.0

E84DGDVB7524

19.8

33.0

I

aNx

Rated value of continuous output current

I

aMx

Maximum output current (overload current)

l

Periodic load change of 3 s with I

aMx

and recovery time of 12 s according to

the tables under chapter

^ 4.4

1)

Operation with an increased rated power only for motor mounting.

Fuses and cable cross−sections

The data/recommendations for operation on a rated mains voltage 400 V can be applied.

(

34)

Advertising