Braking operation – Lenze 8400 motec Manual User Manual

Page 98

Advertising
background image

Braking operation

Braking operation with brake resistor
Wiring of brake resistor

7

l

98

EDS84DG752 EN 4.0

Evaluation of the thermal contact via digital input

The integration of the thermal contact for monitoring the brake resistor can be
implemented via digital input. Use a Lenze system cable. The response to the input signal
must be parameterised using the »Engineer«.

0.37 ... 3 kW

4 ... 7.5 kW

GND-IO

GIO

24O

3.3

k

3.3

k

RB2

RB1

T1 T2

ERB...

E84D...

Rb2

Rb1

X4

X1

DIx

DI...

GND-IO

GIO

24O

3.3

k

3.3

k

RB2

RB1

T1 T2

ERB...

E84D...

Rb2

Rb1

X4

X2

DIx

DI...

8400DDI032 b

8400DDI032 c

E84D...

8400 motec

X4/DIx

free digital input

X1/Rb1,Rb2

Connection of the brake resistor for devices 0.37 ... 3 kW

X2/Rb1,Rb2

Connection of the brake resistor for devices 4 ... 7.5 kW

ERB...

Brake resistor