Safety instructions

Residual hazards

2

l

18

EDS84DG752 EN 4.0

2.3

Residual hazards

Protection of persons

ƒ

Switch off mains voltage before removing the controller (Drive Unit).

ƒ

Before working on the controller, check if no voltage is applied to the power
terminals because

– depending on the device − the power terminals U, V, W, Rb1, Rb2, T1 and T2 remain

live for at least 3 minutes after disconnecting the mains.

– the power terminals L1, L2, L3; U, V, W, Rb1, Rb2, T1 and T2 remain live when the

motor is stopped.

Device protection

ƒ

Connect/disconnect all pluggable terminals only in deenergised condition!

ƒ

Detach the controllers from the installation, e.g. from the motor or mounting wall,
only in deenergised condition!

Motor protection

ƒ

With some settings of the controller, the connected motor can be overheated.

– E.g. longer operation of the DC injection brake.

– Longer operation of self−ventilated motors at low speed.

– Wrong frequency or voltage settings in the motor parameters (especially with

120 Hz motors).

Protection of the machine/system

ƒ

Drives can reach dangerous overspeeds (e.g. setting of high output frequencies in
connection with motors and machines unsuitable for such conditions):

– The controllers do not offer any protection against such operating conditions. Use

additional components for this purpose.

Warning by symbols

Icon

Description

{

Long discharge time:
All power terminals remain live for up to 3 minutes after mains disconnection!

}

High leakage current:
Carry out fixed installation and PE connection in accordance with EN 61800−5−1!

'

Electrostatic sensitive devices:
Before working on the device, the staff must ensure to be free of electrostatic charge!

|

Hot surface:
Use personal protective equipment or wait until devices have cooled down!