EDS84AYCIB EN 4.0 - 11/2010

L

25

E84AYCIB communication manual (INTERBUS)

Installation

Mechanical installation

5.1.2

Mounting for standard devices from 0.55 kW onwards

[5-2]

Mounting for standard devices from 0.55 kW onwards

Mounting steps

1. Slightly impress the pressure surface on the top side of the standard device MCI slot

cover (1).

2. Bend the cover forward and remove it from the standard device (2).
3. Loosen the securing screw for the communication module at the standard device (3).
4. Insert the communication module into the MCI slot of the standard device (4).
5. Tighten the securing screw again (5).

E84YCPM002A