Electrical installation

5.2

Electrical installation

5.2.1

EMC-compliant wiring

In typical systems, standard shielding of the Ethernet cables is sufficient.
However, in environments with a very high level of interference, EMC resistance can be

improved by additionally earthing the cable shield on both sides.
For this observe the following notes:

1. Remove the plastic sheath of the cable on a length of 2 cm.
2. Fasten the cable shield onto the shield contact of the standard device.

5.2.2

Network topology

The bus system must be designed as a ring. Feed and return lines must be integrated in the

same bus cable. The ring goes from the INTERBUS master via all other nodes and back again

to the master.
An INTERBUS ring can consist of maximally 513 nodes (1 master + standard devices

connected).

[5-4]

INTERBUS ring

Documentation for the standard device, control system, plant/machine
Observe the notes and wiring instructions contained in this documentation.

E94YCIB008

M: Master (master control, e.g. PLC, Industrial PC)

S1 ... Sn: Slaves

500 kBit/s:

400 m

2 MBit/s:

£

150 m

£

Inverter Drive

8400

E84AYCIB

X206

X207

Inverter Drive

8400

E84AYCIB

X206

X207

Inverter Drive

8400

E84AYCIB

X206

X207

OUT

IN

OUT

IN

IN

M

S2

S1

Sn