EDS84AYCIB EN 4.0 - 11/2010

L

55

E84AYCIB communication manual (INTERBUS)

Diagnostics

LED status displays

11.1.1

Module status displays

The LEDs MS, ME and DE display the module status.

E84YCIB006

LED

Colour

Status

Description

MS

Green

On

The communication module is supplied with voltage and has

established a connection to the standard device.

Blinking

The communication module is supplied with voltage, but has not

established a connection to the standard device. (Standard device is

switched off, initialising or not present.)

ME

Red

Blinking

An error in the communication module has occurred.

DE

Red

On

The communication module is not accepted by the standard device

(see notes in the documentation for the standard device), or the

standard device is not active.

ME

DE

MS

200 ms

200 ms

200 ms

200 ms