C13880 | reaction on communication failure, C13885 | delete process data, User in – Lenze E84AYCIB User Manual

Page 66: C13881, Has elapsed, the response, C13880/1, Is execut, C13885, E84aycib communication manual (interbus)

Advertising
background image

E84AYCIB communication manual (INTERBUS)

Parameter reference

Parameters of the communication module

66

L

EDS84AYCIB EN 4.0 - 11/2010

C13880

C13881

C13885

Parameter | Name:

C13880 | Reaction on communication failure

Data type: UNSIGNED_8

Index: 10695

d

= 29C7

h

Monitoring response in case of a communication fault

A change in the monitoring response becomes effective immediately.



Communication fault ( 53)

Selection list

0 No response
1 Error
3 Quick stop by trouble
4 Warning locked
6 Information

Subcodes

Lenze setting

Information

C13880/1

0: No response

Response to interrupted INTERBUS communication

;

Read access ; Write access … CINH … PLC-STOP … No transfer … PDO_MAP_RX … PDO_MAP_TX … COM … MOT

Parameter | Name:

C13881 | Monitoring time for Interbus communication failure

Data type: UNSIGNED_16

Index: 10694

d

= 29C6

h

If the "IBS-ACTIVE" status (INTERBUS is active and data are cyclically exchanged) is quit, the response parameterised

in

C13880/1

is executed after the monitoring time set for the data exchange has elapsed.

• The value "65535" in this code deactivates monitoring.

• A change in monitoring is effective immediately.



Communication fault ( 53)

Setting range

(min. value | unit | max. value)

Lenze setting

0

ms

65535 65535 ms

;

Read access ; Write access … CINH … PLC-STOP … No transfer … PDO_MAP_RX … PDO_MAP_TX … COM … MOT

Parameter | Name:

C13885 | Delete process data

Data type: UNSIGNED_8

Index: 10690

d

= 29C2

h

Setting of the process data which the controller is to process further for maintaining internal communication when

the INTERBUS has failed.
Selection list

(Lenze setting printed in bold)

0 Use of the last master process data
1 Process data are set to the value '0'

;

Read access ; Write access … CINH … PLC-STOP … No transfer … PDO_MAP_RX … PDO_MAP_TX … COM … MOT