Diagnostics

Diagnostic data

58

L

EDS84AYCIB EN 4.0 - 11/2010

11.3

Diagnostic data

 Pending diagnostic data are signalised by the master via an alarm message to the slave.
 Errors and warnings in the standard device and the plugged-in module are transmitted

to the master as extended diagnostic messages.

 The diagnostic data can be viewed via the hexadecimal representation of the

Engineering tool.

Error code of the Inverter Drive 8400

[11-1] Structure of the error number

 Bytes 29 ... 32 of the diagnostic message contain the error code of the Inverter Drive

8400.

 The logbook and standard device code C00165 show the error number in the following

syntax to improve the legibility:
[error type].[error subject area no.].[error ID]

Bytes

Meaning

Value [hex]

1 ... 6

Diagnostics block header

0x0010 001C 0100

7 ... 8

Alarm type

0x0001 (Diagnosis)

9 ... 12

API

0x0000 0000

13, 14

Slot number

0x0001 / 0x0002

15, 16

Subslot number

0x0001

17 ... 20

Module ID number

ID according to module

21 ... 24

Submodule number

ID according to module

25, 26

Alarm specifier

0xB000

27, 28

User structure identifier

0x0001

29 ... 32

Error code of the Inverter Drive 8400

A Reserved

B Error type
C Error subject area

D Error ID

2

1

0

3

Bit

16

25

26

31

0

15

29

30

Software manual/»Engineer« online help for the Inverter Drive 8400
Here you'll find detailed information on the structure and the contents of the

error codes.