E84AYCIB communication manual (INTERBUS)

Error messages

Possible causes and remedies

62

L

EDS84AYCIB EN 4.0 - 11/2010

Invalid module configuration [0x01bc6430]

Invalid configuration [0x01bc8125]

Communication stack reset [0x01bc8126]

Invalid initialisation [0x01bc8127]

Data exchange stopped [0x01bc8131]

Response (Lenze setting in bold)

Setting: not possible

…

None … System fault : Fault … Trouble … Quick stop by trouble … Warning locked … Warning … Information

Cause

Remedy

Module configuration is faulty.

Check and correct module configuration.

Response (Lenze setting in bold)

Setting: not possible

…

None … System fault … Fault … Trouble … Quick stop by trouble … Warning locked : Warning … Information

Cause

Remedy

The active configuration is invalid:

• Data word sum (PD + PCP) > 10 words

• Data word sum (PD + PCP) = 0

Adapt the number of PD and PCP:

• Data word sum (PD + PCP) = 1 ... 10 words

Response (Lenze setting in bold)

Setting: not possible

…

None … System fault : Fault … Trouble … Quick stop by trouble … Warning locked … Warning … Information

Cause

Remedy

Error during processing the INTERBUS services

Execute reinitialisation by the master.

Response (Lenze setting in bold)

Setting: not possible

…

None … System fault … Fault … Trouble … Quick stop by trouble … Warning locked : Warning … Information

Cause

Remedy

The INTERBUS initialisation has failed.

Execute reinitialisation by the master.

Response (Lenze setting in bold)

Setting:

C13880/1

:

None … System fault : Fault … Trouble : Quick stop by trouble : Warning locked … Warning : Information

Cause

Remedy

The data exchange at the INTERBUS has been

terminated.

• Check cables and connections.

• Execute reinitialisation by the master.

Advertising