6 external voltage supply, External voltage supply, External voltage supply ( 31) – Lenze E84AYCIB User Manual

Page 31

Advertising
background image

EDS84AYCIB EN 4.0 - 11/2010

L

31

E84AYCIB communication manual (INTERBUS)

Installation

Electrical installation

5.2.6

External voltage supply

The communication module can be supplied externally with voltage via separate supply

cables at the 2-pole plug connector (X205).

 External voltage supply of the communication module is necessary if the bus

communication is to continue when the supply of the standard device fails.

 It is not possible to access the parameters of a standard device that is disconnected

from the mains.

Wiring the X205 plug connector

[5-6]

Wiring of the 2-pole plug connector with spring connection

How to wire the plug connector with spring connection:

1. Place a screwdriver into the notch below the terminal and keep it pressed.
2. Place the supply cable in the terminal.
3. Remove the screwdriver from the notch.

Note!

With external voltage supply, always use a separate power supply unit, safely

separated in accordance with EN 61800-5-1 in every control cabinet ("SELV" /

"PELV").

Stop!

Only wire the plug connector if the standard device is disconnected from the

mains.

E84AYCXX010