EDS84AYCIB EN 4.0 - 11/2010

L

65

E84AYCIB communication manual (INTERBUS)

Parameter reference

Parameters of the communication module

C13861

C13862

C13863

Parameter | Name:

C13861 | Bus status

Data type: BITFIELD_16

Index: 10714

d

= 29DA

h

Display of the current bus status



Querying the current bus status ( 57)

Meaning of the resulting hexadecimal values:

• 0xyyy0 = IBS-INIT

• 0xyyy1 = IBS-ACTIVE

• 0xyyy2 = IBS-READY
Value is bit coded:

Information

Bit 0 Bit 0

... ...

Bit 15 Bit 15

;

Read access … Write access … CINH … PLC-STOP … No transfer … PDO_MAP_RX … PDO_MAP_TX … COM … MOT

Parameter | Name:

C13862 | Counter

Data type: UNSIGNED_16

Index: 10713

d

= 29D9

h

Counter for cycles and INTERBUS resets
Display area

(min. value | unit | max. value)

0

65535

Subcodes

Information

C13862/1

Data cycles per second

C13862/2

Total data cycles

C13862/3

Number of INTERBUS resets

C13862/4

Number of ID cycles

;

Read access … Write access … CINH … PLC-STOP … No transfer … PDO_MAP_RX … PDO_MAP_TX … COM … MOT

Parameter | Name:

C13863 | Active baud rate

Data type: UNSIGNED_8

Index: 10712

d

= 29D8

h

Display of the set baud rate
Selection list

(read only)

0 500 kbps
1 2.00 Mbps

;

Read access … Write access … CINH … PLC-STOP … No transfer … PDO_MAP_RX … PDO_MAP_TX … COM … MOT