background image

Wiring the device

Control terminals

5

100

EDK94SH366 DE/EN/FR/ES/IT 3.1

Digital inputs
”HighLine” version:

Terminal X5

Labelling

Description

GI

GND digital in

RFR

Controller enable

DI1

Digital input 1

DI2

Digital input 2

DI3

Digital input 3

DI4

Digital input 4

DI5

Digital input 5

DI6

Digital input 6

DI7

Digital input 7

9400SSP000X5

DI8

Digital input 8

Terminal data

Conductor cross-section

Tightening torque

[mm

2

]

[AWG]

[Nm]

[lb-in]

Flexible

0.2 ... 2.5

24 ... 12

Spring terminal

With wire end

ferrule

”StateLine” version:

Terminal X5

Labelling

Description

GI

GND digital in

RFR

Controller enable

DI1

Digital input 1

DI2

Digital input 2

DI3

Digital input 3

9400SSPxxx

DI4

Digital input 4