Wiring the device
Power terminals
5
94
EDK94SH366 DE/EN/FR/ES/IT 3.1
Device size 10
SSP94KL110
Fig.5-3
Arrangement of the power connections
Mounting plate
The shield of singles cores and multi-core cables must be connected to the mounting plate
of the control cabinet.
Motor
Terminal X105
Marking
Description
Connection with ring
cable lug for M10
U
V
W
Connection of the motor phases
SSP94KL801
Connection for the PE conductor on the motor side
Terminal data
Max. conductor cross-section
Tightening torque
Screw drive
[mm
2
]
[AWG]
[Nm]
[lb-in]
Device size 10:
E94ASxE4604
E94ASxE5724
E94ASxE6354
E94ASxE6954
2 x 400
3 x 150
2 x 750 mcm
3 x 350 mcm
19
168
WAF 16