Wiring the device modules, Safety modules, Displays – Lenze E94ASHExxxx User Manual

Page 117

Advertising
background image

Wiring the device modules

Safety modules

6

117

EDK94SH366 DE/EN/FR/ES/IT 3.1

Displays

Pos.

Colour

State

Description

MS

Green

On

Drive-based safety is initialised faultlessly.

Blinking

Drive-based safety is initialised faultlessly. Internal

communication to the standard device is not possible.

Off

Drive-based safety is not initialised.

Acknowledgement is not possible.

EN

Yellow

On

Controller enabled

Off

Non-safe display ”STO”

ME

Red

On

System error:

z

After a serious internal error, STO is activated.

z

Can only be reset by switching the 24V supply.

Blinking

Error:

z

After an internal error or an error at the safe inputs, a

standstill function is activated.

z

The safety class is quit.

z

Acknowledgement is possible.

Flashing

Fault:

z

A monitoring function has responded and activated a

standstill function.

z

The safety class is not quit.

z

Acknowledgement is possible.

Off

Error-free operation

PS

Red

On

Error PROFIsafe:

z

Communication is not possible.

z

Acknowledgement is possible.

Blinking

No valid PROFIsafe configuration

Off

PROFIsafe is error-free.

DE

Red

On

The module is not accepted by the standard device (see notes

given in the documentation for the standard device).