Wiring the device modules, Safety modules, Displays – Lenze E94ASHExxxx User Manual
Page 117
Wiring the device modules
Safety modules
6
117
EDK94SH366 DE/EN/FR/ES/IT 3.1
Displays
Pos.
Colour
State
Description
MS
Green
On
Drive-based safety is initialised faultlessly.
Blinking
Drive-based safety is initialised faultlessly. Internal
communication to the standard device is not possible.
Off
Drive-based safety is not initialised.
Acknowledgement is not possible.
EN
Yellow
On
Controller enabled
Off
Non-safe display ”STO”
ME
Red
On
System error:
z
After a serious internal error, STO is activated.
z
Can only be reset by switching the 24V supply.
Blinking
Error:
z
After an internal error or an error at the safe inputs, a
standstill function is activated.
z
The safety class is quit.
z
Acknowledgement is possible.
Flashing
Fault:
z
A monitoring function has responded and activated a
standstill function.
z
The safety class is not quit.
z
Acknowledgement is possible.
Off
Error-free operation
PS
Red
On
Error PROFIsafe:
z
Communication is not possible.
z
Acknowledgement is possible.
Blinking
No valid PROFIsafe configuration
Off
PROFIsafe is error-free.
DE
Red
On
The module is not accepted by the standard device (see notes
given in the documentation for the standard device).