Technical data, Electrical data, Operation at a rated mains voltage of 500 v – Lenze E94ASHExxxx User Manual
Page 77
Technical data
Electrical data
3
77
EDK94SH366 DE/EN/FR/ES/IT 3.1
Rated values for internal brake chopper
Operation at a rated mains voltage of 400 V
Switching
threshold
(adjustable)
Minimum
brake resistor
Peak current
Peak braking
power
Continuous
current
RMS
Continuous
braking
power
Type
U
BRmax
[V]
R
Bmin
[Ω]
I
BRmax
[A]
P
BRmax
[kW]
I
BRd
[A]
P
Bd
[kW]
E94ASxE1454
725
5.0
145
105
79
31.5
E94ASxE1724
725
4.3
169
122
93
36.7
E94ASxE2024
725
3.5
207
150
113
45.1
E94ASxE2454
725
2.8
259
188
142
56.3
E94ASxE2924
725
2.3
315
229
173
68.6
E94ASxE3664
725
1.8
414
300
227
90.1
E94ASxE4604
725
1.4
518
375
227
90
E94ASxE5724
725
1.2
604
438
287
99
E94ASxE6354
725
1.1
659
478
300
99
E94ASxE6954
725
1.1
659
478
300
99
I
BRmax
, P
BRmax
Periodic load change of 0.5 s and recovery time of 4.5 s
R
Bmin
Nominal value, ±10 %
Permanent
current, r.m.s.
R.m.s. value - important for cable dimensioning
Operation at a rated mains voltage of 500 V
Switching
threshold
(adjustable)
Minimum
brake resistor
Peak current
Peak braking
power
Continuous
current
RMS
Continuous
braking
power
Type
U
BRmax
[V]
R
Bmin
[Ω]
I
BRmax
[A]
P
BRmax
[kW]
I
BRd
[A]
P
Bd
[kW]
E94ASxE1454
790
5.0
158
125
87
37.4
E94ASxE1724
790
4.3
184
145
101
43.5
E94ASxE2024
790
3.5
226
178
124
53.5
E94ASxE2454
790
2.8
282
223
154
66.9
E94ASxE2924
790
2.3
343
271
188
81.4
E94ASxE3664
790
1.8
451
357
247
107
E94ASxE4604
790
1.4
564
446
289
117
E94ASxE5724
790
1.2
658
520
312
117
E94ASxE6354
790
1.1
718
567
327
117
E94ASxE6954
790
1.1
718
567
327
117
I
BRmax
, P
BRmax
Periodic load change of 0.5 s and recovery time of 4.5 s
R
Bmin
Nominal value, ±10 %
Permanent
current, r.m.s.
R.m.s. value - important for cable dimensioning