Wiring the device modules

Memory modules

6

111

EDK94SH366 DE/EN/FR/ES/IT 3.1

Note!

If all address switches adopt the ”OFF” position when the basic device is

switched on, the configurations of codes C00350 (nodes address) and C00351

(baud rate) apply.
Switch the voltage supply of the basic device off and then on again to activate

altered settings.

Setting the node address
The node address of the drive is calculated from the sum of all address switches in the ”ON”

position.

Setting the baud rate

d

c

b

a

Baud rate

OFF

ON

ON

OFF

10 kbit/s

OFF

ON

OFF

ON

20 kbit/s

OFF

OFF

ON

ON

50 kbit/s

OFF

OFF

ON

OFF

125 kBit/s

OFF

OFF

OFF

ON

250 kbit/s

OFF

OFF

OFF

OFF

500 kbit/s

ON

ON

ON

OFF

800 kbit/s

OFF

ON

OFF

OFF

1000 kbit/s

OFF

ON

ON

ON

Auto baud