Overview – Lenze E94ASHExxxx User Manual

Page 64

Advertising
background image

64

EDK94SH366 DE/EN/FR/ES/IT 3.1

Overview

Design

Pos.

Description

HighLine StateLine

MXI1

Module receptacle for extension 1, e.g. communication

;

;

MXI2

Module receptacle for extension 2, e.g. communication

;

†

MMI

Module receptacle for memory modules

;

;

MSI

Module receptacle for safety equipment

;

;

X1

System bus (CAN), under the cover

;

†

X2

24-V supply / Statebus

;

;

X3

Analog inputs / analog outputs

2/2

1/0

X4

Digital outputs

4

1

X5

Digital inputs

8

4

X6

Diagnostics (with diagnostic adapter or keypad)

;

;

X7

Resolver

;

;

X8

Encoder

;

;

Lower cap

;

;

Nameplate, retractable

;

;

Upper cap

;

;

EMC wire clamp

Optional

X100

Mains / DC-bus voltage

;

;

X105

Motor / external brake resistor

;

;

X106

Motor temperature monitoring (position depends on the device size)

;

;

X107

Control of motor holding brake

Optional

EMC shield clamp

2

2

Holes for transport and assembly guides

4

4

Shield connection/strain relief (device sizes: 8S, 8 and 9)

;

;

Barrier between mains input and other power terminals (device sizes: 8S, 8

and 9)

;

;

Switch for operation in IT systems

;

;

The LED display enables fast indication of several operating states.

LED

Labelling

Colour

Description

CAN-RUN

green

CAN bus o.k.

Inoperable when ”StateLine” design is

used

CAN-ERR

red

CAN bus error

DRIVE READY

green

Standard device is ready for operation

DRIVE ERROR

red

Error in the standard device or due to the application

24 V

green

24-V supply voltage o.k.

SSP94LED01

USER

yellow

Message parameterised by the application

Pos.

Symbol

Description

Long discharge time: All power terminals carry hazardous voltages for at

least 20 minutes after mains disconnection!

High discharge current: Fixed installation and PE connection to EN 61800-5-1

required!

Electrostatic sensitive devices: Before working on the device, the personnel

must remove any electrostatic charges using suitable measures!

© 2007 Lenze Drive Systems GmbH, Hans-Lenze-Straße 1, D-31855 Aerzen

No part of this documentation may be reproduced or made accessible to third parties without written consent by Lenze Drive

Systems GmbH.

All information given in this documentation has been selected carefully and complies with the hardware and software described.

Nevertheless, discrepancies cannot be ruled out. We do not take any responsibility or liability for any damage that may occur.

Necessary corrections will be included in subsequent editions.