Overview
Design
Pos.
Description
HighLine StateLine
MXI1
Module receptacle for extension 1, e.g. communication
;
;
MXI2
Module receptacle for extension 2, e.g. communication
;
MMI
Module receptacle for memory modules
;
;
MSI
Module receptacle for safety equipment
;
;
X1
System bus (CAN), under the cover
;
X2
24-V supply / Statebus
;
;
X3
Analog inputs / analog outputs
2/2
1/0
X4
Digital outputs
4
1
X5
Digital inputs
8
4
X6
Diagnostics (with diagnostic adapter or keypad)
;
;
X7
Resolver
;
;
X8
Encoder
;
;
Lower cap
;
;
Nameplate, retractable
;
;
Upper cap
;
;
EMC wire clamp
Optional
X100
Mains / DC-bus voltage
;
;
X105
Motor / external brake resistor
;
;
X106
Motor temperature monitoring (position depends on the device size)
;
;
X107
Control of motor holding brake
Optional
EMC shield clamp
2
2
Holes for transport and assembly guides
4
4
Shield connection/strain relief (device sizes: 8S, 8 and 9)
;
;
Barrier between mains input and other power terminals (device sizes: 8S, 8
and 9)
;
;
Switch for operation in IT systems
;
;
The LED display enables fast indication of several operating states.
LED
Labelling
Colour
Description
CAN-RUN
green
CAN bus o.k.
Inoperable when ”StateLine” design is
used
CAN-ERR
red
CAN bus error
DRIVE READY
green
Standard device is ready for operation
DRIVE ERROR
red
Error in the standard device or due to the application
24 V
green
24-V supply voltage o.k.
SSP94LED01
USER
yellow
Message parameterised by the application
Pos.
Symbol
Description
Long discharge time: All power terminals carry hazardous voltages for at
least 20 minutes after mains disconnection!
High discharge current: Fixed installation and PE connection to EN 61800-5-1
required!
Electrostatic sensitive devices: Before working on the device, the personnel
must remove any electrostatic charges using suitable measures!
© 2007 Lenze Drive Systems GmbH, Hans-Lenze-Straße 1, D-31855 Aerzen
No part of this documentation may be reproduced or made accessible to third parties without written consent by Lenze Drive
Systems GmbH.
All information given in this documentation has been selected carefully and complies with the hardware and software described.
Nevertheless, discrepancies cannot be ruled out. We do not take any responsibility or liability for any damage that may occur.
Necessary corrections will be included in subsequent editions.