Wiring the device, Power terminals, Motor temperature monitoring – Lenze E94ASHExxxx User Manual

Page 96: Motor brake control (optional)

Advertising
background image

Wiring the device

Power terminals

5

96

EDK94SH366 DE/EN/FR/ES/IT 3.1

Motor temperature monitoring

Terminal X106

Labelling

Description

T1

T2

Motor temperature monitoring with PTC element (type-A sensor,

switching performance according to EN 60947-8 for type-A tripping

units) or thermostat (NC contact).

SSP94X6106

Terminal data

Max. conductor cross-section

Tightening torque

Screw drive

[mm

2

]

[AWG]

[Nm]

[lb-in]

Flexible

2.5

12

0.5 ... 0.6

4.5 ... 6.2

Slot

0.6 x 3.5

With wire end

ferrule

Motor brake control (optional)

Terminal X107

Labelling

Description
Connection of the motor holding brake

BD1

BD2

+ (Lenze: WH)

- (Lenze: BN)

E94AZHY0101: 24 V DC, max. 5.0 A

Observe correct polarity!

+ / -

Supply voltage for the motor holding brake (18 ... 30 V DC)

Observe correct polarity!

SSP94X6107

Terminal data

Max. conductor cross-section

Tightening torque

Screw drive

[mm

2

]

[AWG]

[Nm]

[lb-in]

Flexible

2.5

12

0.5 ... 0.6

4.5 ... 6.2

Slot

0.6 x 3.5

With wire end

ferrule

Terminal X107

Labelling

Description
Connection of the motor holding brake:

BD1

BD2

+ (Lenze: WH)

- (Lenze: BN)

E94AZHY0025: 205 V DC, max. 0.75 A

Ensure correct polarity!

SSP94A6107

L1

L2/N

Supply voltage of the motor holding brake

Terminal data

Conductor cross-section

Tightening torque

[mm

2

]

[AWG]

[Nm]

[lb-in]

Flexible

0.5 ... 2.5

20 ... 12

Spring terminal

With wire end

ferrule

Stripping length or contact length: 8 mm

Advertising