Wiring the device, Power terminals, Motor temperature monitoring – Lenze E94ASHExxxx User Manual
Page 96: Motor brake control (optional)
![background image](/manuals/565801/96/background.png)
Wiring the device
Power terminals
5
96
EDK94SH366 DE/EN/FR/ES/IT 3.1
Motor temperature monitoring
Terminal X106
Labelling
Description
T1
T2
Motor temperature monitoring with PTC element (type-A sensor,
switching performance according to EN 60947-8 for type-A tripping
units) or thermostat (NC contact).
SSP94X6106
Terminal data
Max. conductor cross-section
Tightening torque
Screw drive
[mm
2
]
[AWG]
[Nm]
[lb-in]
Flexible
2.5
12
0.5 ... 0.6
4.5 ... 6.2
Slot
0.6 x 3.5
With wire end
ferrule
Motor brake control (optional)
Terminal X107
Labelling
Description
Connection of the motor holding brake
BD1
BD2
+ (Lenze: WH)
- (Lenze: BN)
E94AZHY0101: 24 V DC, max. 5.0 A
Observe correct polarity!
+ / -
Supply voltage for the motor holding brake (18 ... 30 V DC)
Observe correct polarity!
SSP94X6107
Terminal data
Max. conductor cross-section
Tightening torque
Screw drive
[mm
2
]
[AWG]
[Nm]
[lb-in]
Flexible
2.5
12
0.5 ... 0.6
4.5 ... 6.2
Slot
0.6 x 3.5
With wire end
ferrule
Terminal X107
Labelling
Description
Connection of the motor holding brake:
BD1
BD2
+ (Lenze: WH)
- (Lenze: BN)
E94AZHY0025: 205 V DC, max. 0.75 A
Ensure correct polarity!
SSP94A6107
L1
L2/N
Supply voltage of the motor holding brake
Terminal data
Conductor cross-section
Tightening torque
[mm
2
]
[AWG]
[Nm]
[lb-in]
Flexible
0.5 ... 2.5
20 ... 12
Spring terminal
With wire end
ferrule
Stripping length or contact length: 8 mm