3 technical data, 1 general data and operating conditions, Technical data – Lenze E94ASHExxxx User Manual

Page 73: 3technical data

Advertising
background image

Technical data

General data and operating conditions

3

73

EDK94SH366 DE/EN/FR/ES/IT 3.1

3

Technical data

3.1

General data and operating conditions

Supply system data
Supply forms

With earthed neutral Unrestricted use
IT systems

Observe instructions about special measures!

Noise emission

EN 61800-3

Cable-guided, up to 150 m motor cable length: category C2
Radiation: category C3

Noise immunity

EN 61800-3

Category C3

Conformity and approval
Conformity

CE

73/23/EEC

Low-Voltage Directive

Approval

UL

UL 508C

Power Conversion Equipment, File No. 132659

Protection of persons and devices
Enclosure

EN 60529

IP 20

Not in the wiring range of

the terminals on the

motor side

NEMA 250

Protection against contact to

type 1

Insulation resistance

EN 61800-5-1

Overvoltage category III

Reduction from 2000 m amsl onwards: Overvoltage category

II

Insulation of control

circuits

EN 61800-5-1

Safe mains isolation by double/reinforced insulation.

Short-circuit strength

EN 61800-5-1

Motor connection: with restrictions, fault acknowledgement

required

Control connections: without restrictions

Motor protective

measures against

z

Short circuit

z

Earth fault

z

Overvoltage

z

Motor stalling

z

Motor overtemperature

(PTC or thermal contact, I

2

t monitoring)

Discharge current

EN 61800-5-1

> 3.5 mA

Observe regulations and

safety instructions!

Cyclic mains switching

Cyclic mains switching of 5-times in 5 minutes permissible

without restrictions.

Environmental conditions
Climate

Storage

IEC/EN 60721-3-1

1K3 (-25 ... +60 °C)

Transport

IEC/EN 60721-3-2

2K3 (-25 ... +70 °C)

Operation

IEC/EN 60721-3-3

3K3 (-10 ... +55 °C)

Power derating at +45 ... +55 °C: 1 %/°C

Site altitude

0 ... 4000 m amsl

Power derating at 1000 ... 4000 m amsl: 5 %/1000 m

Pollution

EN 61800-5-1

Degree of pollution 2

Vibration resistance

IEC/EN 60068-2-6

IEC/EN 60068-2-64

Sinusoidal: 0.7 g RMS, 20 ... 250 Hz

Noise: 0.7 g RMS, 20 ... 250 Hz

Advertising