Wiring the device modules

Safety modules

6

115

EDK94SH366 DE/EN/FR/ES/IT 3.1

Connections

Pos.

Description

PROFIsafe target address switch (on left side of housing)

X82.1

Pluggable terminal strips for input and output signals

X82.2
X82.3
X82.4

Addressing
An unambiguous PROFIsafe target address ensures that a data telegram reaches the

correct node.

DIP switch

Labelling

1

2

3

4

5

6

7

8

9

0

Value of the address bit

1

2

4

8

16

32

64

128

256

512

Note!

The combination of a safety module SM300 of version VA 1.08 or higher and a

PROFIBUS communication module of version VB 0.93 or higher makes it

possible to avoid the error that occurs when an address is set to 0. For this

purpose, a defined PROFIsafe target address must be stored in

C13897 or 14897 of the PROFIBUS communication module.

Terminal assignment

X82.1

Labelling

Description

n. c.

This terminal strip is not assigned.

n. c.
n. c.
n. c.
n. c.
n. c.
n. c.
n. c.
n. c.

X82.2

Labelling

Description

-

GND external supply

+

24 V external supply via a safely separated power supply unit (SELV/PELV)

n. c.

This part of the terminal strip is not assigned.

n. c.
n. c.
n. c.
AIE

Error confirmation input (Acknowledge Input Error)

CLA

Clock output for passive sensors, channel A (clock A)

CLB

Clock output for passive sensors, channel B (clock B)

Advertising