Wiring the device modules – Lenze E94ASHExxxx User Manual
Page 113
Wiring the device modules
Safety modules
6
113
EDK94SH366 DE/EN/FR/ES/IT 3.1
SM100
Function
ƒ
Safe torque off
(previously: safe standstill, protection against unexpected start-up)
SSP94SM112
Fig.6-9
E94AYAB safety module
Connections
Pos.
Labelling
Description
X80
SI1
Input first shutdown path
GI
GND potential for SI1/SI2
SI2
Input second shutdown path
GO
GND potential feedback
24O
24 V voltage supply feedback
DO1
Non-safe signalling output “Safe pulse inhibit”
Terminal data
Conductor cross-section
Tightening torque
[mm
2
]
[AWG]
[Nm]
[lb-in]
Rigid
0.14 ... 1.5
26 ... 16
Spring terminal
With wire end
ferrule
0.25 ... 0.5
24 ... 20
Displays
Pos.
Colour
Condition
Description
EN
Yellow
On
Controller enabled
Off
Non-safe display ”Safe pulse inhibit”
DE
Red
On
The module is not accepted by the standard device (see notes
given in the documentation for the standard device).