Wiring the device, Power terminals, External brake resistor – Lenze E94ASHExxxx User Manual
Page 95: Dc bus, Mains
Wiring the device
Power terminals
5
95
EDK94SH366 DE/EN/FR/ES/IT 3.1
External brake resistor
Terminal X105
Marking
Description
Connection with ring
cable lug for M8
Rb1
Rb2
Connection of external brake resistor
SSP94KL801
Terminal data
Max. conductor cross-section
Tightening torque
Screw drive
[mm
2
]
[AWG]
[Nm]
[lb-in]
Device size 10:
E94ASxE4604
E94ASxE5724
E94ASxE6354
E94ASxE6954
2 x 70
2 x 00
19
168
13
DC bus
Terminal X100
Labelling
Description
Connection with ring
cable lug for M10
+Ug
-Ug
Alternative option for DC-bus voltage connection (compatible to
9300 series).
Terminal data
Max. conductor cross-section
Tightening torque
Screw drive
[mm
2
]
[AWG]
[Nm]
[lb-in]
Device size 10:
E94ASxE4604
E94ASxE5724
E94ASxE6354
E94ASxE6954
2 x 400
3 x 150
2 x 750 mcm
3 x 350 mcm
19
168
WAF 16
Mains
Terminal X100
Marking
Description
Connection with ring
cable lug for M10
L1
L2
L3
Connection of the mains phases
SSP94KL801
Connection for the PE conductor on the supply side
Terminal data
Max. conductor cross-section
Tightening torque
Screw drive
[mm
2
]
[AWG]
[Nm]
[lb-in]
Device size 10:
E94ASxE4604
E94ASxE5724
E94ASxE6354
E94ASxE6954
2 x 400
3 x 150
2 x 750 mcm
3 x 350 mcm
19
168
WAF 16