Wiring the device, Power terminals, External brake resistor – Lenze E94ASHExxxx User Manual

Page 95: Dc bus, Mains

Advertising
background image

Wiring the device

Power terminals

5

95

EDK94SH366 DE/EN/FR/ES/IT 3.1

External brake resistor

Terminal X105

Marking

Description

Connection with ring

cable lug for M8

Rb1

Rb2

Connection of external brake resistor

SSP94KL801

Terminal data

Max. conductor cross-section

Tightening torque

Screw drive

[mm

2

]

[AWG]

[Nm]

[lb-in]

Device size 10:

E94ASxE4604

E94ASxE5724

E94ASxE6354

E94ASxE6954

2 x 70

2 x 00

19

168

13

DC bus

Terminal X100

Labelling

Description

Connection with ring

cable lug for M10

+Ug

-Ug

Alternative option for DC-bus voltage connection (compatible to

9300 series).

Terminal data

Max. conductor cross-section

Tightening torque

Screw drive

[mm

2

]

[AWG]

[Nm]

[lb-in]

Device size 10:

E94ASxE4604

E94ASxE5724

E94ASxE6354

E94ASxE6954

2 x 400

3 x 150

2 x 750 mcm

3 x 350 mcm

19

168

WAF 16

Mains

Terminal X100

Marking

Description

Connection with ring

cable lug for M10

L1

L2

L3

Connection of the mains phases

SSP94KL801

Connection for the PE conductor on the supply side

Terminal data

Max. conductor cross-section

Tightening torque

Screw drive

[mm

2

]

[AWG]

[Nm]

[lb-in]

Device size 10:

E94ASxE4604

E94ASxE5724

E94ASxE6354

E94ASxE6954

2 x 400

3 x 150

2 x 750 mcm

3 x 350 mcm

19

168

WAF 16

Advertising