Wiring the device – Lenze E94ASHExxxx User Manual
Page 89
![background image](/manuals/565801/89/background.png)
Wiring the device
Power terminals
5
89
EDK94SH366 DE/EN/FR/ES/IT 3.1
External brake resistor
Terminal X105
Labelling
Description
Rb1
Rb2
Connection of external brake resistor
Terminal data
Max. conductor cross-section
Tightening torque
Screw drive
[mm
2
]
[AWG]
[Nm]
[lb-in]
Device size 8S:
Flexible
With wire end
ferrule
95
000
14
124
Inbus 5
DC bus
Terminal X100
Labelling
Description
+UG
-UG
Alternative option for DC-bus voltage connection (compatible to
9300 series).
Terminal data
Max. conductor cross-section
Tightening torque
Screw drive
[mm
2
]
[AWG]
[Nm]
[lb-in]
Device size 8S:
Flexible
With wire end
ferrule
95
000
14
124
Inbus 5
Tip!
Now mount the barrier between mains input and power terminals, if had been
removed to have more free space for wiring.
Mains
Terminal X100
Marking
Description
L1
L2
L3
Connection of the mains phases L1, L2, L3
SSP94KL0X8
Connection for the PE conductor on the supply side with M8 ring
cable lug
Terminal data
Max. conductor cross-section
Tightening torque
Screw drive
[mm
2
]
[AWG]
[Nm]
[lb-in]
Device size 8S:
Flexible
With wire end
ferrule
95
000
14
124
Inbus 5
M8 ring cable lug
95
000
9.5
84
WAF 13