Diagnostics

Error messages if communication card MC-CAN2 is not available

13.3

Error messages if communication card MC-CAN2 is not available

If no communication card MC-CAN2 has been inserted into the industrial PC, error mes-

sages occur during the download of the »PLC Designer« project.
Remedy: Insert the communication card MC-CAN2 into the industrial PC.

13.4

Searching the CANopen bus for nodes using the Engineering PC

1. First directly connect your notebook via the USB system bus adapter EMF2177IB to

the CANopen bus.

2. Start the program »System bus configurator«:

• in the »Engineer« in the menu bar under "Online"
• or under "Start - Programs - Lenze - Communication"

3. Activate the USB system bus adapter (EMF2177IB).
4. Check the following under the "Settings" tab:

• baud rate = as on the devices
• parameter data channel = 0:

The entire address range is scanned. Devices responding on several SDO

channels are displayed with several node addresses.

Example:

5. Click the Communication diagnostics button on the Common tab to start the

search.