M1500 SERIES RATINGS

MODEL

INPUT

OUTPUT

(480/590 Vac, 50 - 60 Hz)

(0 - 460/575 Vac)

MODEL

NUMBER

1

FOR MOTORS

NOMINAL

NOMINAL

RATED

INPUT CURRENT

2

POWER

CURRENT

POWER

HP

kW

PHASE

(AMPS)

(KVA)

(AMPS)

(KVA)

M1510

1

0.75

3

1.9 / 1.9

1.9

1.6 / 1.6

1.6

M1520

2

1.5

3

3.3 / 3.3

3.4

2.7 / 2.7

2.7

M1530

3

2.2

3

4.6 / 4.6

4.7

3.9 / 3.9

3.9

M1550/51

5

3.7

3

7.1 / 7.1

7.3

6.1 / 6.1

6.1

M1575

7.5

5.5

3

10.5 / 10.5

10.7

9.0 / 9.0

8.8

M15100

10

7.5

3

12.5 / 12.5

12.8

11.0 / 11.0

11.0

M15150

15

11

3

19.3 / 19.3

19.7

17.0 / 17.0

16.9

M15200

20

15

3

25 / 25

25.4

22 / 22

21.5

M15250

25

18.5

3

31 / 31

31.2

27 / 27

26.9

M15300

30

22

3

36 / 36

37.1

32 / 32

31.9

M15400

40

30

3

47 / 47

47.5

41 / 41

40.8

M15500

50

37.5

3

59 / 59

60.3

52 / 52

51.8

M15600

60

45

3

71 / 71

72.5

62 / 62

61.7

1

Refer to Section 3 for model number breakdown.

2

Refer to Section 8 for recommended fuse type.

Advertising