The following table shows the possible DRIVE STATUS indications that can appear

on the drive display:

DRIVE STATUS TABLE

DISPLAY

DESCRIPTION

STOP

Drive to STOP mode - No output to motor.

RUN

Drive is in RUN mode and is within + 0.3 Hz of the speed set point.

FAULT

Drive has shut down due to a FAULT condition. If the fault condition has

passed, pressing the STOP key will clear the fault and return the drive to the

STOP mode.

LOCK

Drive is in FAULT LOCKOUT after five unsuccessful restart attempts.

BRAKE

DC BRAKE is energized.

LIMIT

Drive is in CURRENT LIMIT due to an overloaded motor,

or ACCEL is set too fast.

F DEC

Drive is in DECEL FREEZE because DECEL is set too fast.

13.2.2 MC1000 DISPLAY IN RUN MODE

When the drive is in the RUN mode, the default display will look like this:

RUN > 60.00 HZ

DRIVE

STATUS

SPEED

SET POINT

SPEED

UNITS

DIRECTION

(FORWARD)

As in the STOP mode, the ENTER key can be used to toggle the display from

SPEED to % LOAD to VAC (motor voltage):

RUN > 85% LOAD

DRIVE

STATUS

PERCENT

LOAD

DIRECTION

(FORWARD)