17 parameter menu, Parameter menu – Lenze MC1000 Series User Manual

Page 45

Advertising
background image

13435742_EDBM101_v24

41

17

PARAMETER MENU

NOTE 1:

REFER TO SECTION 18 - DESCRIPTION OF PARAMETERS

NOTE 2:

MAX LIMIT IS 650 Hz ON UNITS WITH HIGH FREQUENCY SOFTWARE

NOTE 3:

IF LINE VOLTS IS SET TO "LOW" (OR SET TO "AUTO" AND THE INPUT

VOLTAGE IS LOW), THE RANGE IS 25 - 150%.

PARAMETER MENU

PARAM.

NUMBER

PARAMETER

NAME

RANGE OF

ADJUSTMENT

FACTORY

DEFAULT

0

LINE VOLTS

HIGH, LOW, AUTO

AUTO

1

SPEED #1

MIN FRQ - MAX FRQ

20.00 Hz

2

SPEED #2

MIN FRQ - MAX FRQ

20.00 Hz

3

SPEED #3

MIN FRQ - MAX FRQ

20.00 Hz

4

SPEED #4

MIN FRQ - MAX FRQ

20.00 Hz

5

SKIP #1

0.00 Hz - MAX FRQ

0.00 Hz

6

SKIP #2

0.00 Hz - MAX FRQ

0.00 Hz

7

BAND WID

0.00 - 10.00 Hz

1.00 Hz

8

ACCEL

(NOTE 1)

30.0 SEC

9

DECEL

(NOTE 1)

30.0 SEC

10

MIN FRQ

0.00 - MAX FRQ

0.50 Hz

11

MAX FRQ

MIN FREQ - 120.0 Hz (NOTE 2)

60.00 Hz

12

DC BRAKE

(NOTE 1)

0.0 VDC

13

DC TIME

0.0 - 999.9 SEC

0.0 SEC

14

DYN BRAKE

OFF, ON

OFF

16

CURRENT

25 - 180 % (NOTE 3)

180 %

17

MOTOR OL

25 - 100 %

100 %

18

BASE

20.00 - 360.0 Hz (NOTE 2)

60.00 Hz

19

FX BOOST

0.0 - 30.0 %

(NOTE 1)

20

AC BOOST

0.0 - 20.0 %

0.00 %

21

SLIP CMP

0.0 - 5.0 %

0.00 %

22

TORQUE

CONSTANT, VARIABLE,

CT / NOCMP

CONSTANT

23

CARRIER

2.5, 6, 8, 10, 12, 14 kHz

2.5 kHz

25

START

NORMAL, POWER UP,

AUTO RE-, RE-BRAKE

NORMAL

26

STOP

COAST, RAMP, RAMP 2

COAST

27

ROTATION

FORWARD, REVERSE,

FWD&REV, FWD@LOC

FORWARD

Advertising