Lenze MC1000 Series User Manual

Page 22

Advertising
background image

18

13435742_EDBM101_v24

If it is necessary to drill or cut the drive enclosure or panel, extreme care must be

taken to avoid damaging drive components or contaminating the drive with metal

fragments (which cause shorting of electrical circuits). Cover drive components

with a clean cloth to keep out metal chips and other debris. Use a vacuum cleaner

to clean drive components after drilling, even if chips do not appear to be present.

Do not attempt to use positive air pressure to blow chips out of drive, as this tends

to lodge debris under electronic components. Contaminating the drive with metal

chips can cause drive failure and will void the warranty. The MC1000 Series is UL

approved for solid state motor overload protection. Therefore, a separate thermal

overload relay is not required for single motor applications. In applications where

one drive is operating more than one motor, a separate thermal overload relay is

required for each motor per NEC.

7.1

INSTALLATION AFTER A LONG PERIOD OF STORAGE

WARNING!

Severe damage to the drive can result if it is operated after a long

period of storage or inactivity without reforming the DC bus capacitors!

If input power has not been applied to the drive for a period of time exceeding

three years (due to storage, etc), the electrolytic DC bus capacitors within the drive

can change internally, resulting in excessive leakage current. This can result in

premature failure of the capacitors if the drive is operated after such a long period

of inactivity or storage.
In order to reform the capacitors and prepare the drive for operation after a long

period of inactivity, apply input power to the drive for 8 hours prior to actually operating

the drive/motor system.

7.2

EXPLOSION PROOF APPLICATIONS

Explosion proof motors that are not rated for inverter use lose their certification when

used for variable speed. Due to the many areas of liability that may be encountered

when dealing with these applications, the following statement of policy applies:
“Lenze AC Tech Corporation inverter products are sold with no warranty of

fitness for a particular purpose or warranty of suitability for use with explosion

proof motors. Lenze AC Tech Corporation accepts no responsibility for any

direct, incidental or consequential loss, cost, or damage that may arise through

the use of its AC inverter products in these applications. The purchaser

expressly agrees to assume all risk of any loss, cost, or damage that may

arise from such application."

Advertising