3 technical data, 2 protocol data, Technical data – Lenze E84DxxxxxxxxxR User Manual

Page 13: Protocol data, Communication manual 8400 protec profinet, 3technical data

Advertising
background image

EDS84DPNET EN 4.0 - 11/2010

L

13

Communication manual 8400 protec PROFINET

Technical data

General data and operating conditions of the PROFINET

3

Technical data

3.1

General data and operating conditions of the PROFINET

3.2

Protocol data

Mounting instructions "Inverter Drives 8400 protec"
Here you can find information on general technical data, operating conditions,

and rated data of the device.

Field

Values

Communication profile

PROFINET

Communication medium

S/FTP (Screened Foiled Twisted Pair, ISO/IEC 11801 or EN 50173), CAT 5e

Interface

RJ45: Standard Ethernet (in accordance with IEEE 802.3), 100Base-TX (Fast

Ethernet) or M12-socket

Network topology

Tree, star, and line

Number of nodes

Max. 255 in the subnetwork

Max. cable length

100 m

PROFINET node

IO device with real time (RT) communication properties

PUO ID number

0x0106

Device identification (Device ID)

0x8420

Baud rate

100 Mbps

Switching method

"Store and forward"

Switch latency

125 μs at maximum telegram length

Field

Values

Process data words (PCD)

Max. 16 process data words (max. 32 bytes)

PROFIsafe data

4 words (8 bytes)

Acyclic parameter data channel

Limited by the PROFINET frame size