3 diagnostic data, Diagnostic data, Communication manual 8400 protec profinet – Lenze E84DxxxxxxxxxR User Manual

Page 59

Advertising
background image

EDS84DPNET EN 4.0 - 11/2010

L

59

Communication manual 8400 protec PROFINET

Diagnostics

Diagnostic data

11.3

Diagnostic data

 The IO device sends an alarm message to the IO controller to signalise the diagnostic

data below.

Code

C13887

serves to inhibit the transmission of alarm messages to the IO controller.

By this, errors of a specific type can be suppressed systematically.

 Errors and warnings in the Inverter Drive 8400 protec are sent to the IO controller as

extended diagnostic messages.

 The diagnostic data can be displayed using the hexadecimal representation of the

Siemens S7 engineering tool.

Bytes

Meaning

Value [hex]

1 ... 6

Diagnostic block header

0x0010 001C 0100

7 ... 8

Alarm type

0x0001 (Diagnosis)

9 ... 12

API (Application Programming Interface)

0x0000 0000

13, 14

Slot number

0x0001 / 0x0002

15, 16

Subslot number

0x0001

17 ... 20

Module ID

ID according to module

21 ... 24

Submodule number

ID according to module

25, 26

Alarm specification

0xB000

27, 28

User structure ID

0x0001

29 ... 32

Error code of the Inverter Drive 8400 protec