Communication manual 8400 protec profinet – Lenze E84DxxxxxxxxxR User Manual
Page 50
Advertising
![background image](/manuals/566106/50/background.png)
Communication manual 8400 protec PROFINET
Parameter data transfer
Writing parameters to the controller
50
L
EDS84DPNET EN 4.0 - 11/2010
Parameter response after a correct write request
Parameter response after write error
Byte 1
Byte 2
Byte 3
Byte 4
Request reference
Response identifier
Axis
Number of indices
0xXX
0x02
0x00
0x01
(mirrored)
Parameter written
(mirrored)
1 index
Byte 1
Byte 2
Byte 3
Byte 4
Request reference
Response identifier
Axis
Number of indices
0xXX
0x82
0x00
0x01
(mirrored)
Parameter not written
(mirrored)
1 index
Byte 5
Byte 6
Format
Number of values
0x44
0x01
Fault
Error code without additional
information
Byte 7
Byte 8
Error code
High byte
Low byte
For the meaning, see the chapter "