2 possible causes and remedies, Profinet: exist. conn. to 8400 lost [0x01bc3100, Profinet: memory: no access [0x01bc5531 – Lenze E84DxxxxxxxxxR User Manual

Page 62: Profinet: memory: read error [0x01bc5532, Profinet: memory: write error [0x01bc5533, Profinet: restart by watchdogreset [0x01bc6010, Possible causes and remedies, 0x01bc3100, 0x01bc5531, 0x01bc5532

Advertising
background image

Communication manual 8400 protec PROFINET

Error messages

Possible causes and remedies

62

L

EDS84DPNET EN 4.0 - 11/2010

12.2

Possible causes and remedies

This chapter contains all PROFINET error messages in numerical order of the error number.

Possible causes and remedies as well as responses to the error messages are described in

detail.

Tip!
You will find a list of all PROFINET error messages in alphabetical order in the

previous chapter "

Short overview (A-Z) of the PROFINET error messages

"

( 61)

.

PROFINET: Exist. conn. to 8400 lost [0x01bc3100]

PROFINET: Memory: No access [0x01bc5531]

PROFINET: Memory: Read error [0x01bc5532]

PROFINET: Memory: Write error [0x01bc5533]

PROFINET: Restart by watchdogreset [0x01bc6010]

Response (Lenze setting in bold)

Setting: not possible

…

None … System fault : Fault … Trouble … Quick stop by trouble … Warning locked … Warning … Information

Cause

Remedy

• Network cable (plug) is defective.

• Network cable at PROFINET terminal X256 or X257 is

disconnected.

• Voltage supply is interrupted.

Check cables and connections.

Plug in network cable at PROFINET terminal X256 or

X257.

Response (Lenze setting in bold)

Setting: not possible

…

None … System fault : Fault … Trouble … Quick stop by trouble … Warning locked … Warning … Information

Cause

Remedy

Memory could not be accessed.

Send device with error description to Lenze.

Response (Lenze setting in bold)

Setting: not possible

…

None … System fault : Fault … Trouble … Quick stop by trouble … Warning locked … Warning … Information

Cause

Remedy

Parameter could not be read.

Send device with error description to Lenze.

Response (Lenze setting in bold)

Setting: not possible

…

None … System fault : Fault … Trouble … Quick stop by trouble … Warning locked … Warning … Information

Cause

Remedy

Parameter could not be written.

Send device with error description to Lenze.

Response (Lenze setting in bold)

Setting: not possible

…

None … System fault : Fault … Trouble … Quick stop by trouble … Warning locked … Warning … Information

Cause

Remedy

Device is defective.

Send device with error description to Lenze.

Advertising