Communication manual 8400 protec profinet – Lenze E84DxxxxxxxxxR User Manual

Page 48

Advertising
background image

Communication manual 8400 protec PROFINET

Parameter data transfer

Writing parameters to the controller

48

L

EDS84DPNET EN 4.0 - 11/2010

Response header

Parameter format

Error code

Byte 1

Byte 2

Byte 3

Byte 4

Request reference

(mirrored)

Response identifier

Axis

(mirrored)

Number of indices

Field

Data type

Values

Request reference

U8

Mirrored value of parameter request

Response identifier

U8

0x82: Parameter not written

• The data in bytes 7 + 8 are to be interpreted as error

code.

Axis

U8

0x00 or 0x01

Number of indices

U8

0x"n" (n = number of parameters requested)

Byte 5

Byte 6

Format

Number of values

Field

Data type

Values

Format

U8

0x44: Error

Number of values

U8

0x01: Error code without additional information

0x02: Error code with additional information

Byte 7

Byte 8

Byte 9

Byte 10

Error code

Additional information (if available)

High byte

Low byte

High byte

Low byte

Field

Data type

Values

Error code

U16

0x0000 .... 0xFFFF



Error information (error) ( 51)

Additional information

(if available)

U16

Advertising