Communication manual 8400 protec PROFINET

Parameter reference

Parameters relevant for communication

72

L

EDS84DPNET EN 4.0 - 11/2010

C13862

C13864

Parameter | Name:

C13862 | Bus counter

Data type: UNSIGNED_32

Index: 10713

d

= 29D9

h

Display of data cycles per second (irrespective of data changes)
Display range

(min. value | unit | max. value)

0

4294967295

Subcodes

Information

C13862/1

Data cycles per second

C13862/2

Read cycles per second

C13862/3

Write cycles per second

;

Read access … Write access … CINH … PLC-STOP … No transfer … PDO_MAP_RX … PDO_MAP_TX … COM … MOT

Parameter | Name:

C13864 | Active station name

Data type: VISIBLE_STRING

Index: 10711

d

= 29D7

h

Displays the active station name used by the controller.

It may differ from the contents of code

C13899

, depending on whether the station name has been changed via the

fieldbus or via

C13899

.



Setting the station name ( 25)

Subcodes

Information

C13864/1

1st ... 30th character

C13864/2

31st ... 60th character

C13864/3

61st ... 90th character

C13864/4

91st ... 120th character

C13864/5

121st ... 150th character

C13864/6

151st ... 180th character

C13864/7

181st ... 210th character

C13864/8

211th ... 240th character

;

Read access … Write access … CINH … PLC-STOP … No transfer … PDO_MAP_RX … PDO_MAP_TX … COM … MOT