EDS84DPNET EN 4.0 - 11/2010

L

73

Communication manual 8400 protec PROFINET

Parameter reference

Parameters relevant for communication

C13865

C13867

Parameter | Name:

C13865 | Display: Most recent safety PRM data

Data type: OCTET_STRING

Index: 10710

d

= 29D6

h

Display of the most recently sent F_parameters. This data is only valid if PROFIsafe is active.

• The coding of the F_parameters is described in the PROFIsafe profile V2.0.

;

Read access … Write access … CINH … PLC-STOP … No transfer … PDO_MAP_RX … PDO_MAP_TX … COM … MOT

Bytes

Information

0

Slot

1
2

Subslot

3
4

Recldx

5
6

Accepted length

...
9
10

F_parameter

...
24

Parameter | Name:

C13867 | Display: Most recent diagnostic data

Data type: OCTET_STRING

Index: 10708

d

= 29D4

h

Display of most recently diagnostic data sent by the controller:

;

Read access … Write access … CINH … PLC-STOP … No transfer … PDO_MAP_RX … PDO_MAP_TX … COM … MOT

Bytes

Information

0

Slot

1
2

Subslot

3
4

Error code

...
7
8

Slot

9
10

Subslot

11
12

Error code

...