0x2b02, 0x3302, 0x2b03 – Lenze i700 User Manual
Page 139: 0x3303, 5motor control & motor settings

Lenze · i700 servo inverter · Reference manual · DMS 1.5 EN · 03/2014 · TD05
139
5
Motor control & motor settings
5.14
Parameterising the V/f characteristic control
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
0x2B02 | 0x3302 - VFC: User-definable V/f characteristic - frequency grid points (x)
0x2B03 | 0x3303 - VFC: User-definable V/f characteristic - voltage grid points (y)
Sub.
Name
Lenze setting
Data type
1 V/f: x1 = f01
-50 Hz
INTEGER_16
2 V/f: x2 = f02
-40 Hz
INTEGER_16
3 V/f: x3 = f03
-30 Hz
INTEGER_16
4 V/f: x4 = f04
-20 Hz
INTEGER_16
5 V/f: x5 = f05
-10 Hz
INTEGER_16
6 V/f: x6 = f06
0 Hz
INTEGER_16
7 V/f: x7 = f07
10 Hz
INTEGER_16
8 V/f: x8 = f08
20 Hz
INTEGER_16
9 V/f: x9 = f09
30 Hz
INTEGER_16
10 V/f: x10 = f10
40 Hz
INTEGER_16
11 V/f: x11 = f11
50 Hz
INTEGER_16
Write access CINH OSC P RX TX
Sub.
Name
Lenze setting
Data type
1 V/f: y1 = U01 (x = f01)
400.00 V
UNSIGNED_32
2 V/f: y2 = U02 (x = f02)
320.00 V
UNSIGNED_32
3 V/f: y3 = U03 (x = f03)
240.00 V
UNSIGNED_32
4 V/f: y4 = U04 (x = f04)
160.00 V
UNSIGNED_32
5 V/f: y5 = U05 (x = f05)
80.00 V
UNSIGNED_32
6 V/f: y6 = U06 (x = f06)
0.00 V
UNSIGNED_32
7 V/f: y7 = U07 (x = f07)
80.00 V
UNSIGNED_32
8 V/f: y8 = U08 (x = f08)
160.00 V
UNSIGNED_32
9 V/f: y9 = U09 (x = f09)
240.00 V
UNSIGNED_32
10 V/f: y10 = U10 (x = f10)
320.00 V
UNSIGNED_32
11 V/f: y11 = U11 (x = f11)
400.00 V
UNSIGNED_32
Write access CINH OSC P RX TX