Read parameters, Write parameters, 3communication with the controller – Lenze i700 User Manual
Page 35

Lenze · i700 servo inverter · Reference manual · DMS 1.5 EN · 03/2014 · TD05
35
3
Communication with the controller
3.6
Ethernet over EtherCAT (EoE)
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
Read parameters
The service identification (GSV) = 0x82 in the GCI header serves to read parameter data from the
i700 servo inverter:
Write parameters
The service identification (GSV) = 0x83 in the GCI header serves to write parameter data to the i700
servo inverter:
Client
(PC)
Server
(i700)
Request
Request
GMT
GSV
GMQ
GTI
SIZE
SIZE
res
res
User data
Indication
0x01 0x82 0x00 0xXX 0xXX 0xXX
0x00 0x00
Response
Confirmation
GMT
GSV
GMQ
GTI
SIZE
SIZE
res
res
User data
(error code)
Response
0x01 0x82 0x80 0xXX 0xXX 0xXX
0x00 0x00