5motor control & motor settings – Lenze i700 User Manual
Page 66

5
Motor control & motor settings
5.4
Manual control
66
Lenze · i700 servo inverter · Reference manual · DMS 1.5 EN · 03/2014 · TD05
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
Comparison of the test mode "current/frequency" and the "manual control" mode
The following table shows the differences between the two modes:
Test mode "Current/frequency"
Mode "Manual control"
Current setpoint is pending immediately after controller
enable.
• 100 % ≡ rated motor current (
axis B)
Current setpoint is run to the final value via a
parameterisable ramp time after controller enable.
• 100 % ≡ rated axis current (
or
for
axis B)
Axis A
Axis B
Parameter
Axis A
Axis B
Parameter
Current setpoint
Current setpoint (final value)
-
-
(No ramp can be set)
Ramp time
Test frequency is pending immediately after controller
enable.
Test frequency is run up to the final value via a
parameterisable ramp time after controller enable (and
is also run down again). The frequency ramp starts when
the current setpoint has reached its final value.
Axis A
Axis B
Parameter
Axis A
Axis B
Parameter
Test frequency
Test frequency (final value)
-
-
(No ramp can be set)
Ramp time
Starting angle is pending immediately after controller
enable or the rotating field starts with the starting angle.
• In the case of the synchronous motor, a jerky
compensating movement occurs once if the starting
angle does not correspond to the current pole
position of the synchronous motor.
Starting angle is the current commutation angle.
• For the synchronous motor, therefore no
compensating movement should be effected.
Axis A
Axis B
Parameter
Starting angle
Duration unlimited.
(If permitted by the device utilisation and motor
temperature.)
Duration adjustable.
The time starts with the start of the frequency ramp
(when the current setpoint has run up to its final value).
• If the test frequency is not rewritten within the time
set for the time monitoring, the frequency is
decreased to zero via the parameterised ramp.
• When 0 Hz has been reached, the controller changes
to the error status and is inhibited. After the error has
been acknowledged, the "
" device
status has to be changed to the "
"
device status again before manual control can be
continued.
Enable/inhibit operation via control
Axis A
Axis B
Parameter
Time span for time monitoring