9diagnostics & error management – Lenze i700 User Manual
Page 266

9
Diagnostics & error management
9.3
History buffer
266
Lenze · i700 servo inverter · Reference manual · DMS 1.5 EN · 03/2014 · TD05
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
Subindex 3:
Latest acknowledged message
Subindex of the most recent message acknowledged by the EtherCAT master.
Setting range
(min. value | unit | max. value)
Lenze setting
0
255 0
Write access CINH OSC P RX TX
UNSIGNED_8
Subindex 4:
New active message
TRUE if messages are pending that have not been acknowledged by the EtherCAT master yet.
Display area
(min. value | unit | max. value)
Initialisation
0
255 0
Write access CINH OSC P RX TX
UNSIGNED_8
Subindex 5:
Control bits
Settings for the transmission and storage of the messages
Setting range
(min. value | unit | max. value)
Lenze setting
0
65535 0
Write access CINH OSC P RX TX
UNSIGNED_16