9diagnostics & error management – Lenze i700 User Manual
Page 279

Lenze · i700 servo inverter · Reference manual · DMS 1.5 EN · 03/2014 · TD05
279
9
Diagnostics & error management
9.4
CiA402 error codes / error messages
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
Error code 0xFF18: Communication timeout in the manual control mode
Text ID: 0x3F
Error code 0xFF19: Internal error during identification
Text ID: 0x40
Cause
Remedies
Response
In the "manual control" mode,
writing the setpoint data failed to
appear for a longer period of time
|
0x3036:5
.
• Check connection between
device, Controller and »EASY
Starter« or »PLC Designer«.
• Increase the time period in
|
• Restart manual jog dialog.
Fault
Cause
Remedies
Response
Internal error during identification.
Please contact Lenze.
Warning