_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
5.2
Commissioning functions (short overview)
For a quick commissioning, the i700 servo inverter provides various functions which serve to
automatically calculate and set the parameters. These functions can be executed via the following
object:
0x2822 | 0x3022 - Axis command
0x2823 | 0x3023 - Axis command: Progress
Via the cross-reference in the information column, a detailed description of the respective function is provided.
Selection list
(Lenze setting printed in bold)
Info
0 No command
1 Inverter characteristic: Load Lenze setting
Loading the standard inverter characteristic
2 Estimating the optimal magnetising current
Estimating the optimal magnetising current
3 Motor model parameters: Determine from
motor data by approximation
Enter nameplate data and have motor model
parameters determined automatically
4 Current controller: Calculate controller
parameters
Calculate current controller parameters
5 Speed controller: Calculate controller
parameters
Calculate speed controller parameters
6 Position controller: Calculate controller
parameters
Calculate position controller parameters
7 Field controller: Calculate controller
parameters
Calculate field controller parameters
8 Field weakening controller: Calculate
controller parameters
Calculate field weakening controller parameters
9 Identify resolver error
10 VFC: Calculate Imin controller parameters
V/f operation:
Activating the voltage vector control
11 VFC: Calculate Imax controller parameters
V/f operation:
Defining the behaviour at the current
12 VFC: Calculate flying restart controller
parameters
V/f operation:
13 Lh saturation characteristic : Load Lenze
setting
Load standard Lh saturation characteristic
14 Get Hiperface information from encoder
From version 01.03
Read type code, number of increments and number of
distinguishable revolutions out of the encoder and
automatically enter them into the corresponding
Hiperface parameters.
Additional settings for SinCos absolute value encoder
Write access CINH OSC P RX TX
UNSIGNED_32
Display of the current progress of the activated commissioning function
Display area
(min. value | unit | max. value)
Initialisation
0
100 0
Write access CINH OSC P RX TX
UNSIGNED_8