57

5

Motor control & motor settings

5.2

Commissioning functions (short overview)

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

5.2

Commissioning functions (short overview)

For a quick commissioning, the i700 servo inverter provides various functions which serve to

automatically calculate and set the parameters. These functions can be executed via the following

object:

0x2822 | 0x3022 - Axis command

0x2823 | 0x3023 - Axis command: Progress

Via the cross-reference in the information column, a detailed description of the respective function is provided.

Selection list

(Lenze setting printed in bold)

Info

0 No command
1 Inverter characteristic: Load Lenze setting

Loading the standard inverter characteristic

2 Estimating the optimal magnetising current

Estimating the optimal magnetising current

3 Motor model parameters: Determine from

motor data by approximation

Enter nameplate data and have motor model

parameters determined automatically

4 Current controller: Calculate controller

parameters

Calculate current controller parameters

5 Speed controller: Calculate controller

parameters

Calculate speed controller parameters

6 Position controller: Calculate controller

parameters

Calculate position controller parameters

7 Field controller: Calculate controller

parameters

Calculate field controller parameters

8 Field weakening controller: Calculate

controller parameters

Calculate field weakening controller parameters

9 Identify resolver error

Identify resolver error

10 VFC: Calculate Imin controller parameters

V/f operation:

Activating the voltage vector control

11 VFC: Calculate Imax controller parameters

V/f operation:

Defining the behaviour at the current

limit (Imax controller)

12 VFC: Calculate flying restart controller

parameters

V/f operation:

"Flying restart" function

13 Lh saturation characteristic : Load Lenze

setting

Load standard Lh saturation characteristic

14 Get Hiperface information from encoder

From version 01.03

Read type code, number of increments and number of

distinguishable revolutions out of the encoder and

automatically enter them into the corresponding

Hiperface parameters.

Additional settings for SinCos absolute value encoder

with HIPERFACE® protocol

Write access  CINH  OSC  P  RX  TX

UNSIGNED_32

Display of the current progress of the activated commissioning function

Display area

(min. value | unit | max. value)

Initialisation

0

100 0

Write access  CINH  OSC  P  RX  TX

UNSIGNED_8