0x2d40 | 0x3540 - ixt utilisation, 0x2d40, 0x3540 – Lenze i700 User Manual
Page 238: 8monitoring functions

8
Monitoring functions
8.2
Monitoring of the power section and device utilisation (Ixt)
238
Lenze · i700 servo inverter · Reference manual · DMS 1.5 EN · 03/2014 · TD05
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
Parameterisation and evaluation of the monitoring function
The Ixt monitoring function can be parameterised and evaluated via the following indices. Here, a
warning limit and an error limit can be set for each PT1 timing element.
• If the warning threshold (Lenze setting: 95 %) is exceeded, a warning is output in order that the
master is still able to respond if required.
• If the error threshold is exceeded (Lenze setting: 101 %), the inverter is switched off for
protecting the device and generates an error message.
0x2D40 | 0x3540 - Ixt utilisation
Note!
Though continuous operation over 100 % is allowed for by the Ixt monitoring function,
this is nevertheless an impermissible working point!
Sub.
Name
Lenze setting
Data type
Power section utilisation (Ixt): Actual
utilisation
0 %
UNSIGNED_16
Power stage utilisation (Ixt): Warning
threshold
95 %
UNSIGNED_16
Power stage utilisation (Ixt): Error threshold
101 %
UNSIGNED_16
Device utilisation (Ixt): Actual utilisation
0 %
UNSIGNED_16
Device utilisation (Ixt): Warning threshold
95 %
UNSIGNED_16
Device utilisation (Ixt): Error threshold
101 %
UNSIGNED_16
Subindex 1:
Power stage utilisation (Ixt): Actual utilisation
Display area
(min. value | unit | max. value)
Initialisation
0
%
101 0 %
Write access CINH OSC P RX TX
UNSIGNED_16
Subindex 2:
Power stage utilisation (Ixt): Warning threshold
Setting range
(min. value | unit | max. value)
Lenze setting
0
%
101 95 %
Write access CINH OSC P RX TX
UNSIGNED_16
Subindex 3:
Power stage utilisation (Ixt): Error threshold
Display area
(min. value | unit | max. value)
Initialisation
0
%
101 101 %
Write access CINH OSC P RX TX
UNSIGNED_16
Subindex 4:
Device utilisation (Ixt): Actual utilisation
Display area
(min. value | unit | max. value)
Initialisation
0
%
101 0 %
Write access CINH OSC P RX TX
UNSIGNED_16