2 switch on disabled, Switch on disabled, Dged, the – Lenze i700 User Manual
Page 182: Switch-on disabled, Device status, Switch, On disabled, Switch on, Disabled, Device stat

7
CiA402 device profile
7.4
Device control
182
Lenze · i700 servo inverter · Reference manual · DMS 1.5 EN · 03/2014 · TD05
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
7.4.2.2
Switch on disabled
This is the controller's status after the device
has been initialised successfully.
• The process data monitoring is active.
• Communication is possible.
• DC-bus voltage is available.
• The inverter can be parameterised.
• The motor brake, if available, is closed.
• The operation is inhibited.
Bit pattern for the "Switch on disabled" device status in the Statusword (
for axis B):
Bits 15 - 8
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
Warning is
active
Switch on
disabled
Quick stop
Voltage
enabled
Fault active
Operation
enabled
Switched on
Ready to
switch on
X
X
1
X
X
0
0
0
0
Ready to
switch on
Not ready to
switch on
Switched
on
Operation
enabled
Fault reaction
active
Fault
active
Switch on
disabled
Quick stop
active
Power on