0x6049 | 0x6849 - vl velocity deceleration, 3 signal flow (servo control), Signal flow (servo control) – Lenze i700 User Manual
Page 198: 0x6049, 0x6849, 7cia402 device profile, Ctrl

7
CiA402 device profile
7.7
Velocity mode (vl)
198
Lenze · i700 servo inverter · Reference manual · DMS 1.5 EN · 03/2014 · TD05
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
0x6049 | 0x6849 - vl velocity deceleration
7.7.3
Signal flow (servo control)
[7-2]
Signal flow of the servo control in "Velocity mode" (simplified representation)
Short overview of the most important parameters:
Sub.
Name
Lenze setting
Data type
Delta speed
0 rpm
UNSIGNED_32
Delta time
10 s
UNSIGNED_16
Subindex 1:
Delta speed
Setting range
(min. value | unit | max. value)
Lenze setting
0
r/min
2147483647 0 rpm
Write access CINH OSC P RX TX
UNSIGNED_32
Subindex 2:
Delta time
Setting range
(min. value | unit | max. value)
Lenze setting
0
s
65535 10 s
Write access CINH OSC P RX TX
UNSIGNED_16
I
q
I
d
M
CTRL
vl target velocity
Torque offset
Controlword
Lenze control word
Modes of operation
Speed
limitation
Speed
controller
Ramp
function
Statusword
Lenze status word
Modes of operation display
Positive torque limit value
Negative torque limit value
Interpolation
Torque
limitation
Encoder
evaluation
Field-orientated
control
vl velocity actual value
Torque actual value
vl velocity
demand
Position actual value
Function
Object
Name
Axis A
Axis B
Input data
Controlword
Lenze control word
Operating mode: Selection
vl target velocity
Torque offset
Positive torque limit value
Negative torque limit value