3 error codes, Error codes, 3communication with the controller – Lenze i700 User Manual
Page 37

Lenze · i700 servo inverter · Reference manual · DMS 1.5 EN · 03/2014 · TD05
37
3
Communication with the controller
3.6
Ethernet over EtherCAT (EoE)
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
3.6.4.3
Error codes
The error code is located in the User data area P0, byte 1 and byte 2.
Possible error codes
User data area P0
Byte 1
Byte 2
Byte 3
Byte 4
Error code
Data type
Reserved
Example error code 0x9002
Low byte
High byte
0x02
0x90
Note!
The other user data contents correspond to those of an error-free message.
Error code
Definition
Description
Decimal
hex
33803
0x840B
Invalid type
Invalid parameter type
33804
0x840C
Limit violation
Invalid parameter value
33806
0x840E
Unknown parameter
Invalid parameter index
33812
0x8414
Invalid size
Invalid parameter format
33813
0x8415
Not in select list
Parameter is not in the selection list
33814
0x8416
Read not allowed
Parameter read is not allowed
33815
0x8417
Write not allowed
Parameter write is not allowed
33816
0x8418
CINH not set
Controller inhibit is not set
33829
0x8425
Invalid subindex
Invalid parameter subindex
33837
0x842D
Access not allowed
Parameter access not allowed
36873
0x9009
Wrong GMT received
The general telegram identification does not correspond
to the GCI communication.
36874
0x900A
Unknown server request
Internal error in the GCI
36878
0x900E
SRV timeout