0x1c00 - sync manager: communication type, 0x1a16, 0x1c00 – Lenze i700 User Manual
Page 322: 0x1c12, 11 appendix

11
Appendix
11.3
Communication objects
322
Lenze · i700 servo inverter · Reference manual · DMS 1.5 EN · 03/2014 · TD05
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
0x1A16 - Axis B-->TPDO: Additional status information
0x1C00 - Sync Manager: Communication type
0x1C12 - Sync Manager 2 (RPDO-->Device): PDO mapping
Sub.
Name
Lenze setting
Data type
1 (State) B-->TPDO: 0x3033 Lenze Statusword 2
808648720
UNSIGNED_32
2 (State) B-->TPDO: 0x68FD Digital inputs
1761411104
UNSIGNED_32
3 (State) B-->TPDO: xxxx Free config. object 1
0
UNSIGNED_32
4 (State) B-->TPDO: xxxx Free config. object 2
0
UNSIGNED_32
5 (State) B-->TPDO: xxxx Free config. object 3
0
UNSIGNED_32
6 (State) B-->TPDO: xxxx Free config. object 4
0
UNSIGNED_32
7 (State) B-->TPDO: xxxx Free config. object 5
0
UNSIGNED_32
8 (State) B-->TPDO: xxxx Free config. object 6
0
UNSIGNED_32
Write access CINH OSC P RX TX
Sub.
Name
Lenze setting
Data type
1 SM1: Communication type
1: Receive mailbox
UNSIGNED_8
2 SM2: Communication type
2: Transmit mailbox
UNSIGNED_8
3 SM3: Communication type
3: Transit process data
UNSIGNED_8
4 SM4: Communication type
4: Receive process data
UNSIGNED_8
Write access CINH OSC P RX TX
Sub.
Name
Lenze setting
Data type
1 SM2 (RPDO-->Device): Assignment PDO 1
0x1600
UNSIGNED_16
2 SM2 (RPDO-->Device): Assignment PDO 2
0x1604
UNSIGNED_16
3 SM2 (RPDO-->Device): Assignment PDO 3
0x1606
UNSIGNED_16
4 SM2 (RPDO-->Device): Assignment PDO 4
0x1607
UNSIGNED_16
5 SM2 (RPDO-->Device): Assignment PDO 5
0x1610
UNSIGNED_16
6 SM2 (RPDO-->Device): Assignment PDO 6
0x1614
UNSIGNED_16
7 SM2 (RPDO-->Device): Assignment PDO 7
0x1616
UNSIGNED_16
8 SM2 (RPDO-->Device): Assignment PDO 8
0x1617
UNSIGNED_16
9 SM2 (RPDO-->Device): PDO assignment 9
0x0000
UNSIGNED_16
10 SM2 (RPDO-->Device): PDO assignment 10
0x0000
UNSIGNED_16
Write access CINH OSC P RX TX