0x2dd3 | 0x35d3 - target speeds, 0x2dd4 | 0x35d4 - speed controller: output signal, 0x2dd5 | 0x35d5 - torque: target torque – Lenze i700 User Manual
Page 285: 0x2dd3:1, 0x35d3:1, 0x2dd3, 0x35d3, 0x2dd4, 0x35d4, 0x2dd5

Lenze · i700 servo inverter · Reference manual · DMS 1.5 EN · 03/2014 · TD05
285
10
Service/internal
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
0x2DD3 | 0x35D3 - Target speeds
0x2DD4 | 0x35D4 - Speed controller: Output signal
0x2DD5 | 0x35D5 - torque: Target torque
Sub.
Name
Lenze setting
Data type
Speed: Target speed
0 rpm
INTEGER_32
Speed: Target speed 2
0 rpm
INTEGER_32
Speed: Target speed limited
0 rpm
INTEGER_32
Subindex 1:
Speed: target speed
Display area
(min. value | unit | max. value)
Initialisation
-480000
r/min
480000 0 rpm
Write access CINH OSC P RX TX
INTEGER_32
Subindex 2:
Speed: target speed 2
Display area
(min. value | unit | max. value)
Initialisation
-480000
r/min
480000 0 rpm
Write access CINH OSC P RX TX
INTEGER_32
Subindex 3:
Speed: target speed limited
Display area
(min. value | unit | max. value)
Initialisation
-480000
r/min
480000 0 rpm
Write access CINH OSC P RX TX
INTEGER_32
Sub.
Name
Lenze setting
Data type
Speed controller: Output signal 1
0.0 %
INTEGER_16
Speed controller: Output signal 2
0.0 %
INTEGER_16
Subindex 1:
speed controller: output signal 1
Display area
(min. value | unit | max. value)
Initialisation
-3276.7
%
3276.7 0.0 %
Write access CINH OSC P RX TX
Scaling: 1/10
INTEGER_16
Subindex 2:
speed controller: output signal 2
Display area
(min. value | unit | max. value)
Initialisation
-3276.7
%
3276.7 0.0 %
Write access CINH OSC P RX TX
Scaling: 1/10
INTEGER_16
Display area
(min. value | unit | max. value)
Initialisation
-21474836.47
Nm
21474836.47 0.00 Nm
Write access CINH OSC P RX TX
Scaling: 1/100
INTEGER_32