3-2

Configuring the Adapter

If your drive has either an LED or LCD HIM (Human Interface Module),
access parameters in the adapter as follows:

Using an LED HIM

Using an LCD HIM

Using the PowerFlex HIM

Step

Key(s)

Example Screens

1.

Press the ALT and then Sel
(Device) to display the Device
Screen.

2.

Press the Up Arrow or Down
Arrow to scroll to the PROFIBUS
adapter. Letters represent files in
the drive, and numbers represent
ports. The adapter is usually
connected to port 5.

3.

Press the Enter key to enter your
selection. A parameter database
is constructed, and then the first
parameter is displayed.

4.

Edit the parameters using the
same techniques that you use to
edit drive parameters.

Step

Key(s)

Example Screens

1.

In the main menu, press the Up
Arrow or Down Arrow to scroll to
Device Select.

2.

Press Enter to enter your
selection.

3.

Press the Up Arrow or Down
Arrow to scroll to the
PROFIBUS (20-COMM-P)
adapter.

4.

Press Enter to select the
PROFIBUS adapter. A
parameter database is
constructed, and then the main
menu for the adapter is
displayed.

5.

Edit the parameters using the
same techniques that you use
to edit drive parameters.

ALT

Device

OR

Sel

OR

OR

F->

Stopped

Auto

0.00

Hz

Main Menu:
Diagnostics
Parameter

Device Select

Port 5 Device

20-COMM-P

Main Menu:
Diagnostics

Parameter

Device Select