Rockwell Automation 20-COMM-P Profibus Adapter User Manual
Page 80

6-10
Using Explicit Messaging (Parameter Protocol)
Writing Parameter 9 [Comm Fault Action] to the 20-COMM-P on a
PowerFlex 70 (DPI Port 5)
Writing Parameter 15 [Flt Cfg A1 In] to a 20-COMM-P on a PowerFlex
(DPI Port 5)
Confirms Par. Access Word 2 of the request
Message
2000 hex = Change parameter value 8-bit/16-bit
N20:10
Command
2009
1
Par
. Access
W
ord
SLC Address
Descr
iption
Value (he
x)
N10:12
N20:13
N20:12
N20:11
N10:10
N10:13
Reply
3
2
2
1
4
4
3
DPI Port 5 (20-COMM-P)
Not Used
2 hex = 2 dec = Zero Data
Confirms Par. Number of the request ("9")
Transferring 8-bit/16-bit parameter value ("1")
Not Used
Confirms Par. Access Word 4 of the request
9 hex = 9 dec (Pr. 9)
0
5
5
2
0
N10:11
2
1009
Confirms Par. Access Word 2 of the request
Message
3000 hex = Change parameter value (32-bit)
N20:10
Command
300F
1
P
ar
. Access
Wo
rd
SLC Address
Descr
iption
Value (he
x)
N10:12
N20:13
N20:12
N20:11
N10:10
N10:13
Reply
3
2
2
1
4
4
3
DPI Port 5 (20-COMM-P)
Not Used
64 hex = 100 dec = 10.0 Hz
Confirms Par. Number of the request ("F")
Transferring 32-bit parameter value ("2")
Confirms Par. Access Word 4 of the request
F hex = 15 dec (Pr. 15)
0
5
5
64
0
N10:11
64
200F
Confirms Par. Access Word 3 of the request
20COMM-UM006A-EN-P.book Page 10 Friday, September 28, 2001 10:43 AM