Configuring the Adapter

3-7

The following parameters provide information about how the adapter is
configured. You can view these parameters at any time.

Viewing the Adapter Configuration

Number

Name

Description

01

DPI Port

The port on the drive to which the adapter is connected. Usually, it is port
5.

02

DPI Data Rate

The data rate used by DPI in the drive. It will be either 125 kbps or 500
kbps. It is set in the drive, and the adapter detects it.

04

P-DP Addr
Actual

The node address used by the adapter. This will be one of the following
values:

• The address set by the rotary switches.

• The value of Parameter 03 - [P-DP Addr Cfg] if the switches have

been disabled.

• An old address of the switches or parameter if they have been

changed and the adapter has not been reset.

06

Ref/Fdbk Size

The size of the Reference/Feedback. It will either be 16 bits or 32 bits. It is
set in the drive and the adapter automatically uses the correct size.

07

Datalink Size

The size of the Datalinks. It will either be 16 bits or 32 bits. It is set in the
drive and the adapter automatically uses the correct size.

12

DPI I/O Active

The Reference/Feedback and Datalinks are used by the adapter. This
value is the same as Parameter 11 - [DPI I/O Config] unless the
parameter was changed and the adapter was not reset.

Bit Definitions
0 = Cmd/Ref
1 = Datalink A
2 = Datalink B
3 = Datalink C
4 = Datalink D
5 = Not Used
6 = Not Used
7 = Not Used